Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Influence of Thermo-Light Curing with Dental Light-Curing Units on the Microhardness of Glass-Ionomer Cements
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 36 , Issue 3
May/June 2016

Pages 425–430


Influence of Thermo-Light Curing with Dental Light-Curing Units on the Microhardness of Glass-Ionomer Cements

Lidia Gavic, DMD, PhD/Kristina Gorseta, DMD, MS, PhD/Ali Borzabadi-Farahani, DDS, MScD, MOrth RCS (Ed)/Antonija Tadin, DMD, PhD/Domagoj Glavina, DMD, MS, PhD/Raymond N. van Duinen, DDS, PhD/Edward Lynch, BDSc, MS, PhD, FDS RCS


PMID: 27100813
DOI: 10.11607/prd.2405

The purpose of this study was to verify for various glass-ionomer cement (GIC) products whether the application of thermo-light curing on the initial curing material produces an increase in microhardness, and to determine whether this hardness varies depending on the depths of the GIC samples. The efficacy of various polymerization units on this additional hardening was also examined. The GIC samples were thermo-light cured for 60 seconds with three polymerization units. The Vickers microhardness was measured at three different depths: 2 mm, 3 mm, and 4 mm. Analysis of variance and Newman-Keuls test showed statistically significant differences among tested samples for all three GIC groups (P < .001). The results of linear regression analysis showed a statistically significant relationship between the hardness of the material and the temperature for samples with depths of 2 mm (R = 0.78; P = .0028) and 3 mm (R = 0.59; P = .045). The findings of this study indicate that thermo-light curing of GIC with different polymerization units for 60 seconds during setting reaction increases the microhardness of the GICs at all depths tested and may increase resistance to mastication forces, which can be validated in future clinical studies.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help